Camps amagats
Llibres Llibres
" The incision of the cornea is to be made with the smallest possible Graefe's knife, in the following manner : "Puncture and contrapuncture are made in the sclerotic about one millimetre beyond the cornea, the whole remaining incision passing with a very... "
The Indiana Journal of Medicine - Pàgina 470
editat per - 1871
Visualització completa - Sobre aquest llibre

St. Louis Medical and Surgical Journal, Volum 10

1873 - 712 pàgines
...puncture and contra-puncture, which are placed about one millimetre beyond it in the sclerotic(i) — the whole remaining incision passing with a very slight curve through the cornea, so that the centre of it is about ii-2 millimetres within the margin of the cornea, and, consequently, nearly in...
Visualització completa - Sobre aquest llibre

Diseases and Injuries of the Eye: Their Medical and Surgical Treatment

George Lawson - 1874 - 426 pàgines
...LIEBRECH'S OPERATION POR CATARACT. — The following is Dr. Liebreich's description of his operation : — "The incision of the cornea is to be made with the...very slight curve through the cornea, so that the centre of it is about one millimetre and a half distant from the margin of the cornea, fig. 43. This...
Visualització completa - Sobre aquest llibre

British and Foreign Medico-chirurgical Review: Or, Quarterly ..., Volum 51

1873 - 556 pàgines
...With a Graefe's knife, puncture and contra-puncture are made in the sclerotic about one millemetre beyond the cornea, the whole remaining incision passing...very slight curve through the cornea, so that the centre of it is about one millemetre and a half distant from the margin of the cornea, and the traction...
Visualització completa - Sobre aquest llibre

Diseases and injuries of the eye

George Lawson - 1880 - 454 pàgines
...LIEBREICH'S OPERATION FOR CATARACT. — The following is Dr. Liebreich's description of his operation : — "The incision of the cornea is to be made with the...Graefe's knife, in the following manner. "Puncture andcontra-puncture are made in the sclerotic about one millimetre beyond the cornea, the whole remaining...
Visualització completa - Sobre aquest llibre

A Manual of the diseases of the eye

Nottidge Charles MacNamara - 1882 - 570 pàgines
...CATARACT.— The following OPERATION is Mr. Liebreich's description of his operation : — FOR CATA- The incision of the cornea is to be made with the...very slight curve through the cornea, so that the centre of it is about one millimetre and a half distant from the margin of the cornea. This incision...
Visualització completa - Sobre aquest llibre

Canada Lancet, Volum 4

1872 - 622 pàgines
...recommended by Graefe, which ho had formerly employed, and finds it to be, in many respects, its superior. The incision of the cornea is to be made with the...about one millimetre beyond the cornea, the whole of the remaining incision passing with a very slight curve through the cornea, so that the centre of...
Visualització completa - Sobre aquest llibre

American Armamentarium Chirurgicum

George Tiemann & Co - 1989 - 938 pàgines
...puncture and counterpuncture, which are placed about one millimetre beyond it in the sclerotic — the whole remaining incision passing with a very slight curve through the cornea, so that the centre of it is about one and one-half or two millimetres within the margin of the cornea. All the...
Previsualització limitada - Sobre aquest llibre

The Cincinnati Lancet and Observer, Volum 33

1872 - 970 pàgines
...original plan ; and I proposed, therefore, in 1867, in an article on Cataract which I wrote for the Noveau Dictionnaire de Medecine et de Chirurgie (Paris, Bailliere),...Puncture and contrapuncture are made in the sclerotic abont one millimetre beyond the cornea, the whole remaining incision passing with a very slight curve...
Visualització completa - Sobre aquest llibre

The Indian Medical Gazette, Volum 8

1873 - 358 pàgines
...definitely settled as a favorable mode of operating. 312 313 Puncture and contra-puncture to be situated in the sclerotic about one millimetre beyond the cornea, the whole remaining incision to pass with a very slight curve through the cornea, so that the centre of it is about one millimetre...
Visualització completa - Sobre aquest llibre

St. Louis Medical and Surgical Journal, Volum 10

1873 - 710 pàgines
...extraction, arising out of the height of the flap, I 'propose a new method of extraction, which is to be made in the following manner : — " Puncture and contra-puncture are made in the sclerotic about i mm. beyond the cornea ; the whole remaining incision is to pass, with a very slight curve, through...
Visualització completa - Sobre aquest llibre




  1. La meva biblioteca
  2. Ajuda
  3. Cerca avançada de llibres
  4. Baixeu EPUB
  5. Descarrega PDF